Products
MILTON ROY, Electromagnetic Dosing Pumps Excel AD By introducing the new EXCEL™ AD8 and AD9 electromagnetic pumps, Milton Roy Europe offers its expertise to the users by providing reliable and easy to use electromagnetic pumps.
Thanks to its numerous programming functions, the AD9 series could suit any process. Benefits
- Easy to use: the (calculated) dosing rate is displayed in l/h or GPH
- Fully compatible with most chemicals used
- Can be adapted to suit the process: control can be manual, by pulse, by 4-20 mA signal, sequential via timer, batch injection, pulse division/multiplication, 24 VDC output, remote on/off
- Wide injection range
- Display of the pump status
- High pumping capacity due to double-ball check valves
- Dosing of products requiring automatic degassing (concentrated bleach, etc.) with AutoPrime™ liquid ends
- Dosing of high viscosity products
- Monitoring of product transfer operation: single or dual level switch available as option
Read More
MILTON ROY, Electronmagnetic Dosing Pumps LMI C Main Technical Features- Available liquid ends: PVC, stainless steel, design for viscous products (stainless steel – up to 1,350 cP)
- Maximum flow rate: 2.14 l/h
- Maximum pressure: 50 bar max. with stainless steel liquid end / 25 bar max. with PVC liquid end
- Accuracy: ± 2% over a range of 10 to 100% of the nominal flow rate
- Linear stroke frequency adjustment: while running or stopped. C1 series: from 1 to 100 spm, C7 series: from 5 to 100 spm, C9 series: from 1 sph to 100 spm
- Linear stroke length adjustment: from 10% to 100% recommended
- Thrust: 400 N
- Temperatures of pumped fluids: stainless steel liquid ends: -5 °C to +50 °C as standard / PVC liquid end: +10 °C to +50 °C
- Maxium ambient temperature: +50 °C
- Protection: IP65
- Maximum viscosity: standard liquid ends: 45 cP / XV liquid end for viscous products: 1,350 cP
- Suction lift: 6 mWC primed
- Minimum discharge pressure: 2 bar
- Valves: double valve and double ball as standard
- Flow rate variation from 1 to 100%
- Stroke frequency and stroke length manually adjustable
- This operating mode allows for a larger flow rate with a reduced cost
- Stroke frequency and stroke length manually adjustable
- Pump stroke frequency varies automatically with the main flow rate. Control via dry contact or open collector originating from a water meter or pulse generator. Optional adapters MICROPACE – multiply, divide, convertor 4-20 mA – can be used to adapt the pump to different control modes
- Optional low level safety device to prevent loss of priming
- Electronically adjustable power control
- Manually adjustable stroke length and frequency from 1 to 6,000 stroke per hour
- Remote start/stop, proportional pulse control, integrated multiplier and divider, configurable 4-20 mA signal control, pulse copying, alarm display
- Optional low level alarm and self-monitoring flow system
- Electronically adjustable power control
Download